Furnaces
 
Freedom® 90 Two-Stage Furnace
Uses a minimum of fuel for all the heating you need.
Specification

  • Provides two-stage heating, running at an energy-saving 65% capacity more than 80% of the time, which reduces temperature swings and may help lower your heating bills*
  • Converts up to 93% of the fuel you pay for into heat for your home
  • Significantly surpasses government efficiency standards, helping you save on your energy bills while reducing greenhouse gas emissions*
  • Operates quietly and efficiently with its multispeed blower motor
  • Its heavy steel insulated cabinet is durable, quiet, and holds more heat in the furnace to better warm your home
  • Its cleanable filter can be rinsed or vacuumed, saving you the trouble of buying replacement filters
*Potential energy savings may vary depending on your lifestyle, system settings, equipment maintenance, local climate, home construction and installation of equipment and duct system.
 
Upflow/Horizontal
Model TONNAGE Stage 1 Capacity Stage 2 Capacity H" W" D" Shipping Weight (lb)
AUX060R936W 3 36,000 56,000 40.0 17.5 28.0 156
AUX080R942W 3 48,000 73,000 40.0 17.5 28.0 168
AUX100R948W 4 60,000 93,000 40.0 21.0 28.0 197
AUX120R960W 5 72,000 112,000 40.0 24.5 28.0 206

Downflow/Horizontal
Model TONNAGE Stage 1 Capacity Stage 2 Capacity H" W" D" Shipping Weight (lb)
ADX060R936W 3 36,000 55,000 40.0 17.5 28.0 160
ADX080R942W 3 48,000 74,000 40.0 17.5 28.0 168
ADX100R948W 4 60,000 93,000 40.0 21.0 28.0 185
ADX120R960W 5 72,000 111,000 40.0 24.5 28.0 206

Single- or two-pipe vent options; direct drive four-speed motor; integrated solid state controls with self-diagnostics; silicon nitride igniter; multi-port in-shot burners; heavy gauge aluminized steel primary heat exchanger; AL29-4C stainless steel secondary heat exchanger; insulated blower compartment; up to 93 AFUE; LP convertible; cleanable high-velocity filter; PVC vent; approved for use in mobile homes.

As an ENERGY STAR® Partner, American Standard Heating & Air Conditioning has determined that some models meet the ENERGY STAR® guidelines for energy efficiency.

 
............................................................................................................................................................................................................................................................................................................
 
Freedom® 90 High Efficiency Single-Stage Furnace
Freedom® 90 High Efficiency Single-Stage Furnace
16_icon_heats.gif17_icon_afue_93.gif18_icon_energystar.gif

Key Benefits:

  • Converts up to 92% of the fuel you pay for into heat for your home
  • Significantly surpasses government efficiency standards, helping you save on your energy bills while reducing greenhouse gas emissions*
  • Operates quietly and efficiently with its multispeed blower motor
  • Its heavy steel insulated cabinet is durable, quiet, and holds more heat in the furnace to better warm your home
  • Its cleanable filter can be rinsed or vacuumed, saving you the trouble of buying replacement filters

*Potential energy savings may vary depending on your lifestyle, system settings, equipment maintenance, local climate, home construction and installation of equipment and duct system.

 
Specifications

Upflow Horizontal Left
Model TONNAGE Capacity AFUE H" W" D" Shipping Weight (lb)
AUX1B040A9H21B 2 38,000 92.10 40.0 17.5 28.0 139
AUX1B060A9H31B 3 56,000 92.10 40.0 17.5 28.0 150
AUX1B080A9H31B 3 74,000 92.10 40.0 17.5 28.0 158
AUX1C100A9H41B 4 94,000 92.10 40.0 21.0 28.0 171
AUX1D120A9H51B 5 113,000 92.10 40.0 24.5 28.0 205

Downflow Horizontal Right
Model TONNAGE Capacity AFUE H" W" D" Shipping Weight (lb)
ADX1B040A9H31B 3 38,000 91.00 40.0 17.5 28.0 145
ADX1B060A9H31B 3 56,000 91.00 40.0 17.5 28.0 155
ADX1B080A9H31B 3 74,000 91.00 40.0 17.5 28.0 168
ADX1C100A9H41B 4 94,000 91.00 40.0 21.0 28.0 185
ADX1D120A9H51B 5 112,000 91.00 40.0 24.5 28.0 206

Convertible to horizontal; Up to 92.1AFUE.

............................................................................................................................................................................................................................................................................................................
Freedom® 90 Single-Stage Furnace
16_icon_heats.gif17_icon_afue_93.gif18_icon_energystar.gif
Key Benefits:
  • Converts up to 92% of the fuel you pay for into heat for your home
  • Significantly surpasses government efficiency standards, helping you save on your energy bills while reducing greenhouse gas emissions*
  • Operates quietly and efficiently with its multispeed blower motor
  • Its heavy steel insulated cabinet is durable, quiet, and holds more heat in the furnace to better warm your home

*Potential energy savings may vary depending on your lifestyle, system settings, equipment maintenance, local climate, home construction and installation of equipment and duct system.

 
Specification
Direct/Non-Direct Vent - Upflow/Horizontal
Model TONNAGE Capacity AFUE H" W" D" Shipping Weight (lb)
AUX1B040A9241A 2 38,000 92.1 40 17.5 28 139
AUX1B060A9361A 3 56,000 92.1 40 17.5 28 150
AUX1B080A9421A 3.5 74,000 92.1 40 17.5 28 158
AUX1C080A9601A 5 76,000 92.1 40 21 28 171
AUX1C100A9481A 4 94,000 92.1 40 21 28 171
AUX1D100A9601A 5 93,000 92.1 40 24.5 28 197
AUX1D120A9601A 5 113,000 92.1 40 24.5 28 205

Direct/Non-Direct Vent - Downflow/Horizontal
Model TONNAGE Capacity AFUE H" W" D" Shipping Weight (lb)
ADX1B040A9241A 2 38,000 91.0 40 17.5 28 145
ADX1B060A9361A 3 56,000 91.0 40 17.5 28 155
ADX1B080A9421A 3.5 74,000 91.0 40 17.5 28 168
ADX1C100A9481A 4 94,000 91.0 40 21 28 185
ADX1D120A9601A 5 112,000 91.0 40 24.5 28 206

Convertible to horizontal; cleanable high velocity filters; up to 92.1AFUE; lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner; 5-year limited parts warranty.

As an ENERGY STAR® Partner, American Standard Heating & Air Conditioning has determined that some models meet the ENERGY STAR® guidelines for energy efficiency.

............................................................................................................................................................................................................................................................................................................
 
AUH2 American Standard Furnace
AUH2 - American Standard high efficiency ( condensing) forced air gas furnace provides efficient and reliable two stage heat and variable speed blower. Cozy World - your home heating and air conditioning contractor is an American Standard HVAC dealer.
AUH2 American Standard gas furnace is made on the same  assembly line as Trane gas furnace and the furnaces are almost identical.
 
  • This furnace provides two-stage heating, running at an energy-saving 65% capacity more than 80% of the time, that reduces temperature swings and lowers your heating bills
  • AUH2 gas furnace converts up to 96.7% of  gas you are paying for into heat for your home
  • Significantly surpasses government efficiency standards,  saving on your energy bills while reducing greenhouse gas emissions
  • Runs quietly and evenly distributes warm air to every room with its variable speed fan motor
  • 2 pipe design (direct vent) completely separates combustion area from your home
  • No mandatory tune-ups every year
  • In the summer, Comfort-R™ helps keep your home cooler by reducing indoor humidity
  • Every American Standard forced air gas furnace has heavy steel insulated cabinet.  It is durable, quiet, and holds more heat in the furnace to better warm your home.
    For your piece of mind, Parts and Labour Extended Factory Warranties for up to 10 years are available for American Standard gas furnaces. The underwriter of the warranties is Trane Corporation.
    The warranty is transferable to another owner if you are moving. Also, you are free to change your servicing company to another American Standard or Trane dealer.
 
RESOURCES
  • American Standard Gas Furnace Owner's Manual
  • AUH2 Furnace Specs
  • American Standard Heating and Cooling Products Web Site
 
............................................................................................................................................................................................................................................................................................................
 
Softsound VS 95 Variable-Speed Two-Stage Gas Furnace
 
Consistent Comfort
The two-stage system operates at low heat most of the time and automatically modulates to higher heat production if the temperature drops. Run the high efficiency fan continuously to improve indoor air quality. The variable-speed motor can also help increase comfort by maximizing moisture removal during cooling operation.

Reliable
Direct Hot Surface Ignition System features an advanced silicon nitride igniter for years of reliable starts.

Durable
The RPJ® III primary heat exchanger is made of corrosion-resistant weld-free stainless steel. The unique integrated ripple-edged design forces more heat to the outside surface area for higher efficiencies.

Heating On Demand
Two-stage redundant gas valve, two-speed induced draft blower assembly, and variable-speed motor operate normally at the lower stage and ramp up as needed.

Quiet
Variable-speed circulation blower motor is pre-lubricated, dynamically balanced, and resilient mounted to reduce vibration and noise.

System Monitoring
State-of-the-art electronic controls monitor system operation and allow for advanced diagnostics, a timesaving tool for technicians.
  • Energy-saving high efficiency operation of 95% AFUE.
  • Two-stage operation system reduces temperature and humidity swings in the home by heating and cooling more evenly.
  • 10 year No Hassle Replacement™ limited warranty* gives you a replacement unit if the heat exchanger should fail within the first ten years.
  • Lifetime limited warranty* on the primary and secondary heat exchanger.
  • 10 year limited warranty* on all functional parts.
  • HELP® (Homeowner’s Extended Labor Program) available.
PS92 Gas Furnace
 
Durable
Advanced RPJ® III primary and stainless steel secondary heat exchanger capture additional heat generated by your furnace.

Quiet
Induced draft combustion blower for efficient performance.Direct vent for quieter operation.

Reliable
Multispeed PSC circulation blower for durability and reliability.
  • Energy-saving 92% AFUE.
  • 20 year limited warranty* on the heat exchanger.
  • 10 year limited warranty* on all functional parts.
  • HELP® (Homeowner’s Extended Labor Program) available.